• Rolling stock – AC vehicles
  • Rolling stock – AC/DC multisystem vehicles

AC voltage & current sensors

Sécheron’s TMS voltage and current sensor complies with EN50463 standard and provide accurate output signals for energy measurement, vehicle protection and control functions. TMS also delivers catenary voltage detection information to the vehicle’s TCMS.

  • Rolling stock – AC vehicles
  • Rolling stock – AC/DC multisystem vehicles

AC voltage & current sensors

Sécheron’s TMS voltage and current sensor complies with EN50463 standard and provide accurate output signals for energy measurement, vehicle protection and control functions. TMS also delivers catenary voltage detection information to the vehicle’s TCMS.

Main benefits

  • Accuracy class 0,5 R suitable for Energy Measurement
  • Optional AC and DC Catenary Voltage Detection function
  • No delay / jitter between inputs / outputs
  • Ideal also for traction control, train control & protection
  • Current loop transmission for noise immunity
  • Insulated outputs
  • Optional output offset for safety critical applications
  • Outputs compatible with Sécheron MACS AC circuit breaker for switching synchronization and protection functions
  • Compact and lightweight
  • Safe against internal arcs
  • Simple electronic architecture without embedded software
  • Extensively tested to safety & reliability
  • Certified TSI Loc&Pass
  • Expert customer support
  • Worldwide after-sales service

Product environment

Sécheron TMS is a versatile Traction Measurement System for rail vehicles. It provides AC voltage and current measurement signals wtih an accuracy class 0,5 R, suitable for energy measurement, traction control and vehicle protection. As an option, the TMS can also provide the AC or DC catenary voltage detection information, as well as a DC voltage measurement signal with an accuracy class of 0.5 R suitable for energy measurement.

The TMS configurations cover the standalone Voltage Measurement Function (VMF) as well as the combined Voltage and Current Measurement Functions (VMF and CMF). They transmit safe, isolated, and accurate signals to a variety of on-board equipment.

The TMS is available on a stand-alone basis so that car builders and operators can install it on the vehicle roof. It can also be integrated into our smart, compact MODBOX® high-voltage enclosure with other high- and low-voltage functions for the electrical safety, measurement and control of the traction chain.

If you are looking for a more comprehensive solution, the TMS can also be delivered as part of the Sécheron Hasler Energy Metering System with energy meter including the Energy Calculation Function (ECF) and the Data Handling System (DHS).

All of our components and solutions are backed by Sécheron expert service during all phases of your project. Let us recommend the best solution to meet your needs. Whatever your choice, you can count on efficient support worldwide for the entire lifetime of your product.

Brochures

  • TMS Measurement Sensors
    Language
    Download
  • High-voltage integrated systems MODBOX
    Language
    Download
  • Supply program for rail transportation
    Language
    Download
AC voltage & current sensors

Product description

  • 3 outputs for AC voltage measurement class 0,5 R

  • 1 output for DC voltage measurement class 0,5 R

  • 2 outputs for AC current measurement class 0,5 R

  • 4 digital outputs for Catenary Voltage Detection

  • Measurement of any AC catenary voltage from 11 kV to 25 kV, with frequency between 16.7 Hz and 60 Hz

  • Measurement of any DC catenary voltage between 750 V and 3 kV

  • Measurement of vehicle input current from 100 A to 630 A (15 kVAC) and from 60 A to 400 A (25 kVAC)

  • Insulation voltage 31.5 kVAC

  • Impulse withstand voltage 170 kV

  • Auxiliary supply voltage 24 to 110 VDC

  • Vertical & horizontal installation

  • Indoor or outdoor installation

  • Compact & lightweight

  • Suitable for ambient temperature –40°C to +70°C

  • Reference standards: EN 50463-2 / IEC 62888-2, IEC 61869-2, EN/IEC 60044-7

  • Insulation material according to EN 45545-2

 